HOME  DEUTSCH  FRANÇAIS
red-y for gasflow Voegtlin Instruments AG
red-y smart series
           
  Technical overview 'red-y smart series'  
           
smart series:
» Overview
» Instrument Types
» Technical Data
» PDF-Datasheet
» Contact
Instrument versions   standard hi-performance  
  Accuracy ± 1.0% of full scale ± 0.3% of full scale and ± 0.5% of reading
  Turndown ratio 1 : 50 1 : 100 (higher on request)
     
Performance data Media Air, O2, N2, He, Ar, CO2, H2, CH4, C3H8
    Other gases and gas mixtures on request
  Response time 50 ms
  Repeatability ± 0.2% of full scale
  Longterm stability < 1% of measured value / year
  Power supply 24 Vdc (18 – 30 Vdc), 15 Vdc on request
  Current drawn Meter: max. 100mA
    Controller: max. 250mA
  Operation pressure 0.2 – 11 bar a
  Temperature 0 – 50°C
  Materials Anodized aluminium, optional stainless steel electropolished
  Seals FKM, optional EPDM
  Pressure sensitivity < 0.2% / bar of reading (typical N2)
  Temperature sensitivity < 0.025% FS measuring range type / °C
     
Measuring Ranges Type Measuring range (Air), Full scale freely selectable Connection
red-y smart meter GSM-A from 0 ... 25 mln/min to 0 ... 600 mln/min G1/4"
  GSM-B from 0 ... 600 mln/min to 0 ... 6000 mln/min G1/4"
  GSM-C from 0 ... 6 ln/min to 0 ... 60 ln/min G1/4"
  GSM-D from 0 ... 60 ln/min to 0 ... 450 ln/min G1/2"
red-y smart controller GSC-A from 0 ... 25 mln/min to 0 ... 600 mln/min G1/4"
  GSC-B from 0 ... 600 mln/min to 0 ... 6000 mln/min G1/4"
  GSC-C from 0 ... 6 ln/min to 0 ... 60 ln/min G1/4"
  GSC-D from 0 ... 60 ln/min to 0 ... 450 ln/min G1/2"
     
Integration Output signals:  
  - analog 0..20 mA, 4..20 mA, 0..5 V, 1..5 V, 0..10 V, 2..10 V
  - digital RS-485; Modbus RTU (Slave); Lab View-VI‘s available
Optional: ProfiBus DP-V0, DP-V1
  Process connection G¼“ female less than 60 ln/min, G½“ female less than 450 ln/min
  Inlet section None required
  Electrical connection Sub D plug, 9 pole
  Mounting orientation Any orientation (horizontal only above 5 bar)
     
Safety Test pressure 16 bar a
  Leak rate < 1 x 10-6 mbar l/s He
  Environ. protection IP-50
  EMC EN 61326-1
     
Software 'get red-y' View flow rate & temperature – Graphical display of measured data
  Change setpoints – Select measured gas and mixtures
  Option: Datalogging, Gasmixer
  > More Information about PC-Software 'get red-y'